Results block #3 (cont’d) – Rockwell Automation 5370 Color CVIM Communications Manual User Manual

Page 189

Advertising
background image

Appendix C
Numerical Results Data

C–10

Table C.3
Numerical Results Data–Results Block 2 (cont’d)

Word #

PI

Backplane

RS–232

and

Remote

I/O

Bit #

Definition

Usage

Notes

204

44

0–15

Reference Window #3

Theta (Integer)

16.16 value. Refer to Appendix A. Only if
2 or 3 Features are enabled.

205

45

0–15

Reference Window #3

(Fraction)

Only if 2 or 3 Features are enabled.

206

46

0

Reference Window X1/Y1

Pass/Fail Bit

0 = Pass
1 = Fail

Feature #1 16 Bit integer

206

46

1

Reference Window X2/Y2

Pass/Fail Bit

0 = Pass
1 = Fail

Feature #2 16 Bit integer

206

46

2

Reference Window X3/Y3

Pass/Fail Bit

0 = Pass
1 = Fail

Feature #3 16 Bit integer

206

46

3

Combination Pass/Fail Bit

0 = Pass
1 = Fail

0 if all enabled tools pass.

206

46

4–15

Not Used

207

47

0–15

Score Reference Window #3

Feature #1

208

48

0–15

Score Reference Window #3

Feature #2

209

49

0–15

Score Reference Window #3

Feature #3

210

50

0–15

Brightness Probe Red Integer

16.16 value

211

51

0–15

Brightness Probe

Red Fraction

16.16 value

212

52

0–15

Brightness Probe

Green Integer

16.16 value

213

53

0–15

Brightness Probe

Green Fraction

16.16 value

214

54

0–15

Brightness Probe Blue Integer

16.16 value

215

55

0–15

Brightness Probe

Blue Fraction

16.16 value

216–217

56–57

0–15

Reserved

218

58

0–15

Reserved

219

59

0–15

Task Missed Triggers

16 Bit integer

220

60

0–15

Task Master Faultsr — Most

Significant Word

32 Bit Integer. Increments if at least 1 tool
fails.

221

61

0–15

Task Master Faultsr — Least

Significant Word

222

62

0–15

Task Triggersr — Most

Significant Word

32 Bit Integer.

223

63

0–15

Task Triggersr — Least

Significant Word

Results Block #3 (cont’d)