Using output signal timing data (cont’d) – Rockwell Automation 5370 Color CVIM Communications Manual User Manual

Page 28

Advertising
background image

Chapter 3
Using Local I/O

3–8

In Figure 3.3, trigger pulse #2 occurs before the Color CVIM module has
finished the pulsed output duration of the outputs from trigger #1.

Figure 3.3
Timing Diagram — Trigger #2 During Data Valid, Pulsed I/O

Strobe

2ms

Min. trigger

2ms*

MODULE

BUSY

**

***

**

***

**

***

Trigger

pulse #1

Trigger

pulse #2

Trigger

(Input)

STROBE

DATA

VALID

RESULTS

MASTER

RANGE

Max. lag

1ms

* As seen by the Color CVIM when the trigger is directly connected through the JMB

board, and not provided by a host device.

** Minimum acquisition time: 17ms for 256x256 and 512x256 Res; 34 ms for 512x512 res.

*** Analysis time (variable).

DATA VALID will always pulse high when
inspection processing is complete

Trigger

pulse #3

For Trigger #1

****

****

****

You can select
a pulse width
of 1 to 2000 ms

****RESULTS will pulse high if an analysis tool range is exceeded.

Using Output Signal
Timing Data (cont’d)