Configuration blocks 46–109 – Rockwell Automation 5370 Color CVIM Communications Manual User Manual

Page 210

Advertising
background image

Appendix D
Configuration Data

D–11

Table D.8
Configuration Blocks #41, 43, & 45 – Reference Windows 1–3 (cont’d)

Remote I/O

& RS–232

Word #

Bit #

Definition

Usage

Notes

42

0–15

Feature 3 Search Window Height

43–46

0–15

Reserved

47

0–7

Reserved

47

8–15

Feature 3 Score

0 = Minimum Value
100 = Maximum Value

48–58

0–15

Reserved

Table D.9 shows the function of each word in the gage 1–64 configuration
blocks.

Table D.9
Configuration Blocks #46–109 – Gages 1–64

Remote I/O

& RS–232

Word #*

Bit #

Definition

Usage

Notes

0

0–15

Block Transfer Signature

1

0

Enable

0 = Disabled
1 = Enabled.

1

1–15

Reserved

2–3

0–15

Reserved

4

0–7

X–Line High Threshold/
Scale Factor

0–197

4

8–15

Image Number

0–37

5

0–7

Reserved

5

8–15

X–Line Low Threshold/
Scale Factor

6

0–15

Gage Head X Position

7

0–15

Gage Head Y Position

8

0–15

Gage Tail X Position

9

0–15

Gage Tail Y Position

10

0–15

Gage X Center Position
(Circular Gage)

11

0–15

Gage Y Center Position
(Circular Gage)

12

0–15

Reserved

13–16

0–15

Reserved

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.