Appendix D
Configuration Data

D–5

Table D.2
Configuration Block #2 – Camera Definition (cont’d)

Remote I/O

& RS–232

Word #*

Bit #

Definition

Usage

Notes

24

0–15

Warning Range Low for Red
Channel (Fraction)

25–28

0–15

Reserved

29

0–15

Fail Range High for Green Channel
(Integer)

Words 29 and 30 represent a 16(bit).16(bit)
fixed point decimal value.

30

0–15

Fail Range High for Green Channel
(Fraction)

31

0–15

Fail Range Low for Green Channel
(Integer)

Words 31 and 32 represent a 16 (bit). 16 (bit)
fixed point decimal value.

32

0–15

Fail Range Low for Green Channel
(Fraction)

33

0–15

Warning Range High for Green
Channel (Integer)

Words 33 and 34 represent a 16 (bit).16 (bit)
fixed point decimal value.

34

0–15

Warning Range High for Green
Channel (Fraction)

35

0–15

Warning Range Low for Green
Channel (Integer)

Words 35 and 36 represent a 16 (bit). 16 (bit)
fixed point decimal value.

36

0–15

Warning Range Low for Green
Channel (Fraction)

37–40

0–15

Reserved

41

0–15

Fail Range High for Blue Channel
(Integer)

Words 41 and 42 represent a 16(bit).16(bit)
fixed point decimal value.

42

0–15

Fail Range High for Blue Channel
(Fraction)

43

0–15

Fail Range Low for Blue Channel
(Integer)

Words 43 and 44 represent a 16 (bit). 16 (bit)
fixed point decimal value.

44

0–15

Fail Range Low for Blue Channel
(Fraction)

45

0–15

Warning Range High for Blue
Channel (Integer)

Words 45 and 46 represent a 16 (bit).16 (bit)
fixed point decimal value.

46

0–15

Warning Range High for Blue
Channel (Fraction)

47

0–15

Warning Range Low for Blue
Channel (Integer)

Words 47 and 49 represent a 16 (bit). 16 (bit)
fixed point decimal value.

48

0–15

Warning Range Low for Blue
Channel (Fraction)

49

0–15

Reserved

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.