Using the RS–232 Ports

5–16

Use this command to read the results of the last inspection. Refer to
Appendix B for a description of the results blocks. Use the following
commands:

>RRx,o,d [CR]

Where:

x

=

Number of times command is
repeated.

o

=

RL (specifies Reference Line)
RW (specifies Reference Window)
G (specifies Gage)
W (specifies Window)
LP (specifies Light Probe)

d

=

Gage, Window, Reference Line, or
Reference Window number.

>RR [CR]

Reads all discrete bit results.

>RRx,P1 [CR]

Reads discrete bit first part results.
x = Number of times command is repeated.

>RRx,P2 [CR]

Reads discrete bit second part results.
x = Number of times command is repeated.

>RRx,RB,d [CR]

Reads results block(s).
x = Number of times command is repeated.
d = Block number.

>RRx, S [CR]

Reads Color CVIM module status.