Appendix C
Numerical Results Data

C–15

The sixth results block can be configured via either the RS–232 or Remote
I/O. There are up to three configurations for this block. There is a unique
configuration for each RS–232 port. The Remote I/O channel configures the
block used for Remote I/O and backplane. See Table C.6.

Table C.6
Results Block #6

Word #

PI

Backplane

RS–232

and

Remote I/O

Bit #

Function

Notes

352

0

0–15

Block Transfer Signature

353

1

10–15

Status

The contents of
this word will be 0 if
all of the requested
data fits in the 64
word results block.
Otherwise, the
contents will be
non–0.

354–413

2–61

0–15

User Defined Inspection

Results Data

414–415

62–63

0–15

Task Triggers (32 Bits)

Each type of result requires a specific number of words. Use the following as
a guideline when setting up a programmable block transfer:

NUMBER OF WORDS

FORMAT

Module Status

1 Word

X/Y Reference Line

2 Words

16 Bit Integer

Window

2 Words
(Object & Pixel)

32 Bit Integer

(Luminance)

16 Point 16

(Color Match)

32 Bit Integer

(Color ID)

32 Bit Integer

(Gradient)

32 Bit Integer

Brightness Probe

6 Words

16 Point 16

Reference Window

14 Words

16 Bit Integer
and
16 Point 16

Gage

2 Words
(Linear Measure)

16 Point 16

(Edge, Pixel, Object)

32 Bit Integer

X, Y Position

16 Point 16

Results Block #6