Chapter 5
Using the RS–232 Ports

5–47

Use this command to read the results of the last inspection. Refer to
Appendix C for a description of the results blocks. Use one of the following
commands:

07 00 n times x z

Where:

07 =

Read Command

00 =

Always 00

n times =

Value for repeat read

x =

00 (Specifies All Discrete Bit Results)
04 (Specifies Bit Besults First Part)
05 (Specifies Bit Results Second Part)
08 (Specifies Color CVIM module status)
10 (Specifies Results Block)
16 (Specifies Gage)
17 (Specifies Window)
18 (Specifies Reference Line)
19 (Specifies Reference Window)
1A (Specifies Light Probe)

z =

Number of window or gage being read or block result
number.

n times

07

00

04

Use this command to read the discrete bit results first part.

n times

07

00

05

Use this command to read the discrete bit results second part.

n times

07

00

10

Data

Use this command to read results blocks.

Where data results block number.