Select image displayed – Rockwell Automation 5370 Color CVIM Communications Manual User Manual
Page 89

Chapter 5
Using the RS–232 Ports
5–21
Use the display object commands to select the information that is displayed
on the monitor:
>W,D,d [CR]
Where d is the data that specifies the display to be viewed:
d = 1 (Image only displayed)
or 2 (Failed tools displayed)
or 3 (All tools displayed)
or 4 (I/O page displayed)
or 5 (Results page displayed)
or 6 (Stats 1 page displayed)
or 7 (Stats 2 page displayed)
or 8 (Page up same display)
or 9 (Page down same display)
>W,F,d [CR]
d = 1 (Go on reject)
or 2 (Freeze on 1st reject)
or 3 (Freeze on all rejects)
or 4 (Freeze on next inspection)
or 5 (Halt on reject)
>w,DC,d [CR]
d = 1 (Resume)
or 2 (Reset stats)
or 3 (Reset counters)
or 8 (Page up)
or 9 (Page down)
Example:
>W,D,2[CR]
This example will display failed tools.
After executing the command, the Color CVIM module will return:
[CR][LF]. No data is returned. If you do not have the proper command
structure, the Color CVIM module will return: ?[CR][LF].
Select Image Displayed