Command summary – Rockwell Automation 5370 Color CVIM Communications Manual User Manual

Page 95

Advertising
background image

Chapter 5
Using the RS–232 Ports

5–27

After you have become familiar with the ASCII commands, you can use the
following command summary as a quick reference guide.

Table 5.A
ASCII Command Summary

Command

Command Structure

Field Descriptions

Deactivate Forces

>DF [CR]

Disable Outputs

>DO [CR]

Enable Outputs

> EO [CR]

Echo Data

>E, data [CR]

Data = ASCII string

Force Outputs

>F, On, d [CR]

n =

1 to 14

d =

0 or 1

Load Configuration From
EEPROM to RAM

>LO [CR]

Load Configuration From RAM
Card to RAM

>LO, CC, d[CR]

d =

1 to 16*

Lock

>L [CR]

Unlock

>U [CR]

Read Output Condition

>R, On [CR]

n =

1 to 14

Read Configurable Statistics

>RSn [CR]

n =

number of times read

Read Configuration

>RC, CBn [CR]

n =

1 to 213

Read All Discrete Bit Results

>RR [CR]

Read Discrete Bit Results

>RR, Pn [CR]

n =

1 or 2

Read Results Block

>RR, RB, d [CR]

>RR,o,d[CR]

>RR,S

**

d = 1, 2, 3, 4, 5, or 6

o =

RL,RW,G,W,LP

d =

gage or window number

S =

Status

Save to EEPROM from RAM

>S [CR]

Save to RAM Card from RAM

>S, CC, d [CR]

d = 1 to 16*

Set Configurable Results

>SR,d,d,etc. [CR]

d =

G1,G2,W1,W2,
RW1, RL3, LP, etc.

*

The number of configurations that can be stored on a RAM card depends upon the card
size (512K card can hold 16 configurations).

**

Refer to Appendix B, Table B.1, RS–232 word 0 for a definition of Color CVIM status.

Command Summary

Advertising