Chapter 4
Using the Remote I/O Link

4–13

Rung 2:4
When Data Valid bit is high, read the discrete results for window 1, then
light the correct status light.
| Data Valid |
| for the Window 1 |Window 1 |Pass |
| TS warning |Fault |light |
| I:020 I:021 I:021 O:000 |
+––––] [––––––––––––––––––––––––––––––––––––+–––]/[––––––––]/[––––––––( )––––+–+
| 06 | 00 01 10 | |
| |Window 1 Fail | |
| |Fault light | |
| | I:021 O:000 | |
| +–––] [–––––––––––––––––––( )––––+ |
| | 01 11 | |
| |Window 1 |Window 1 |Warning | |
| |warning |Fault |light | |
| | I:021 I:021 O:000 | |
| +–––] [––––––––]/[––––––––( )––––+ |
| 00 01 12 |

Rung 2:5
Tells the Color CVIM to display All Tools Page
| Display |
| All Tools All Tools |
| Page Page |
| DISPLAY |
| B3 O:021 |
+––––] [––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+–––(L)––––+–+
| 4 | 02 | |
| |I/O Page | |
| | O:021 | |
| +–––(U)––––+ |
| | 03 | |
| |Results | |
| |Page | |
| | O:021 | |
| +–––(U)––––+ |
| 04 |

Rung 2:6
Tells the Color CVIM to display the results page.
| Display All Tools |
| I/O Page Page |
| DISPLAY |
| B3 O:021 |
+––––] [––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+–––(U)––––+–+
| 5 | 02 | |
| |I/O Page | |
| | O:021 | |
| +–––(L)––––+ |
| | 03 | |
| |Results | |
| |Page | |
| | O:021 | |
| +–––(U)––––+ |
| 04 |

Example Program For