Select image displayed – Rockwell Automation 5370 Color CVIM Communications Manual User Manual
Page 119

Chapter 5
Using the RS–232 Ports
5–51
Use the display object command to control the image that is displayed on the
monitor. Use the following commands:
The data in this command specifies the display to be viewed.
01 (hex) = Image only displayed
02 (hex) = Failed tools displayed
03 (hex) = All tools displayed
04 (hex) = I/O page displayed
05 (hex) = Results page displayed
06 (hex) = Stats 1 page displayed
07 (hex) = Stats 2 page displayed
08 (hex) = Page up same display
09 (hex) = Page down same display
0B
13
Data
The data in this command specifies the display to be viewed.
01 (hex) = Go on reject
02 (hex) = Freeze on first reject
03 (hex) = Freeze on all reject
04 (hex) = Freeze on next inspection
05 (hex) = Halt on reject
0B
14
Data
The data in this command specifies the display to be viewed.
01 (hex) = Resume
02 (hex) = Reset Statistics
03 (hex) = Reset counters
04 (hex) = Page up
05 (hex) = Page down
Select Image Displayed