Command summary (cont’d) – Rockwell Automation 5370 Color CVIM Communications Manual User Manual

Page 96

Advertising
background image

Chapter 5
Using the RS–232 Ports

5–28

Table 5.A

ASCII

Command Summary (Cont’d)

Command

Command Structure

Field Descriptions

Set Configurable Statistics

>SSn,d,d,etc. [CR]

n =

number of samples.

d =

G1, G2, W1, W2,
RW1, LP, etc.

Trigger Inspection

>T,[CR]

Write Display

>W, D, data [CR]

Data = 1 to 9

1 = Image only
2 = Failed Tools
3 = All Tools
4 = I/O Page
5 = Results Page
6 = Stats 1 Page
7 = Stats 2 Page
8 = Page Up
9 = Page Down

>W, F, data [CR]

Data = 1 to 5

1 = Go On Reject
2 = Freeze On First Reject
3 = Freeze On All Rejects
4 = Freeze On Next Inspection
5 = Halt On Reject

>W, DC, data (CRI

Data = 1 to 9

1 = Resume
2 = Reset Statistics
3 = Reset Counters
8 = Page Up
9 = Page Down

Write Configuration BIock(W)

>W, CBn [CR] data

n = 1 to 213
Data= ASCII
configuration data

Write Configuration Block(WC)

>WC,CBn,CBn,etc. [CR] data

n = 1 to 213
Data = ASCII
configuration data

Command Summary (cont’d)

Advertising