Chapter 5
Using the RS–232 Ports

5–12

Figure 5.3
Memory Requirements for Images and Configurations

Image 1–11

Image 1–12

Config 3

Config 4

Config 1

Config 2

Image 1–1

Image 1–2

Image 1–3

Image 1–4

Image 1–5

Image 1–6

Image 1–7

Image 1–8

Image 1–9

Image 1–10

2801–MD5

Memory Card

Slot #

1
2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Note: Memory cards are laid out in slots. A 64K card (2801–MD4) has
room for two configurations. The 512K memory card (2801–MD5) has 16
slots, and can store up to 16 configurations. An image must be one of the
first two items stored to the 512K card, and will occupy 12 contiguous free
slots.

Use the lock command to disable the setup menu box so that the SETUP
mode cannot be entered using the light pen. This function can only be
executed once per command. There is no object associated with this
command. The command has the following structure:

>L[CR]

After executing a command, the Color CVIM module will return: [CR][LF].
No data is returned by the command. If you do not have the proper command
structure the Color CVIM module will return: ?[CR][LF]. Use the unlock
command to enable the setup menu box.

Lock Command

Advertising