30

MAIN\

Job Settings

MC

Station setup and
orientation by given azimuth

Station data

Call the Station function from the Job Settings dialog.

MAIN\ Enter Station Data

Station Id :

ST1

Inst. Ht. :

1.600 m

Stn. East :

0.000 m

Stn. North :

0.000 m

Stn. Elev. :

0.000 m

Hz

:

12.1300 g

CONT

REC SetHz IMPOR

MC

To import station coordinates from data job

Enter the Station Id and the instrument height.
You can enter the station coordinates manually or import
them from the data job.

F1

STN

1

This function is used for station setup and instrument orientation,
given the station coordinates and the azimut to a backsight point.