Fnc fixed function key, 35 utility functions – Leica Geosystems TPS1100 Professional Series - System Field Manual User Manual

Page 35

Advertising
background image

35

Utility functions

List of the functions available in the dialog “Measure & Record”.

To set a new value for the horizontal angle circle reading.

To modify the display content according to the predefined display
masks:
• Standard 1: Angles and distances
• Standard 2: Offset and Coordinates
• Standard 3: Point Code and Attributes

To manually enter a distance.

To delete the last block registered in the measurement job.
The last block can be a measurement or a code block.

Motorized instruments: changing between face I and face II.
Manual instruments: displaying the Hz- and V-differences up to the
other face. The instrument must be moved manually by the user
until the differences are 0.

To enter an individual point Id. After the entry of the individual point
Id, the running point Id is displayed again.

F5

SETHZ

F6

>DISP

F2

D INP

F3

DEL B

F4

I<>II

F5

INDIV

FNC Fixed function key

The fixed key

provides direct access to additional functions,

which might be needed during measurement (see next chapter).