Quick Set with
orientation to one backsight
point

This function is used for station setup and instrument orientation,
given the station coordinates and the coordinates of one backsight
point.
You can enter the station/ backsight coordinates manually or import
them from the data job.
Call the Quick Set function from the Job settings dialog.

Enter the Station Id. If available, the coordinates are
automatically retrieved from the data job.

Enter the Backsight Id.

Press to view the coordinates of the
highlighted value (Station or Backsight Id).

Main\

Job settings

MC

Main\ Quick station setup

Station Id :

ST1

Backs. Id. :

BS200

Inst. Ht. :

1.650 m

Refl. Ht. :

1.700 m

∆∆∆∆∆HorizDist :

----- m

Measure to Backs.point