EDM Program selection

Call the dialog for EDM program selection from the function
selection dialog.

Select the target type. This function is only available on
instruments with the option "reflectorless EDM".
Select corresponding EDM program:
Standard or Fast distance measurement.
Tracking or Rapid Tracking
Average: the parameter “AVG n max”allows you to set the

maximal number of distances to be averaged (from 2 to 999
distances).

To accept the selection and return the dialog from which FNC has
been started.
For more details, refer to the chapter “EDM functions”.

FNC\ Function selection

MC

FNC\ EDM Parameters

Set EDM Prog. for DIST/ALL:

Target Typ :

Reflector

EDM Prog. :

Standard

Refl.list : Leica circ.prism

Add.const. :

0.0 mm