EDM Program selection
Call the dialog for EDM program selection from the function
selection dialog.
Select the target type. This function is only available on
instruments with the option "reflectorless EDM".
Select corresponding EDM program:
• Standard or Fast distance measurement.
• Tracking or Rapid Tracking
• Average: the parameter “AVG n max”allows you to set the
maximal number of distances to be averaged (from 2 to 999
distances).
To accept the selection and return the dialog from which FNC has
been started.
For more details, refer to the chapter “EDM functions”.
FNC\ Function selection
MC
FNC\ EDM Parameters
Set EDM Prog. for DIST/ALL:
Target Typ :
Reflector
EDM Prog. :
Standard
Refl.list : Leica circ.prism
Add.const. :
0.0 mm