FNC\ Function selection

MC

F1

CONT

Compensator

FNC\

Compensator

Compensator ON/OFF

Hz Corrections ON/OFF

Compensat. :

On

Hz-Corr.

:

On

CONT

MC

Call the Compensator dialog from the function selection dialog.

Select the compensator and Hz corrections settings:

To return to the dialog from which FNC has been started.

Compensat. =
ON

V-angles are corrected and relate to the plumb
line.

Compensat. =
OFF

V-angles are not corrected and relate to the
standing axes.

Hz-corr. = ON

Hz-angles are corrected for Hz/V collimation.
Standing-axis tilt is corrected only if
Compensat.=ON.

Hz-corr. = OFF

Hz-angles are not corrected.