55 example: measure & record dialog – Leica Geosystems TPS1100 Professional Series - System Field Manual User Manual
Page 55
![background image](/manuals/651976/55/background.png)
55
Example: Measure & Record dialog
F1
ALL
F2
DIST
To automatically position the telescope to the prism centre,
measure angles and distance, and record measurement data.
To automatically position the telescope to the prism centre,
measure and display the distance to the prism.
ATR is also active in the function, for setting the orientation
to a reflector with following procedure:
• Approximatively aim at the reflector.
• Enter the azimuth value. ATR will position the telescope to the
reflector centre.
• Set the orientation.
If you want to use to set the orientation to a target without
prism, you first need to switch ATR off.
F5
SetHz
F5
SetHz
Meas\ Measure & Record
Point Id
:
123
Refl. Ht
:
1.700 m
Hz
:
222.3444 g
V
:
82.3467 g
Horiz.Dist :
----- m
Elev.Diff. :
----- m
ALL
DIST
REC
SetHz >DISP
MC