2-1 Mounting and Wiring the Sensor Amplifier

2-4

2

Installation and C

onnection

IL-E

Panel mount type, main unit (IL-1500)

1

Make a hole on the panel as shown in the diagrams below.

2

Insert the amplifier into the panel.

3

Arrange the panel mounting bracket as shown below, attach the bracket
to the amplifier from the back and attach the front protection cover to the
amplifier.

To remove the panel mounting bracket, widen the claws at both ends of the panel
mounting bracket using a screwdriver, etc. and remove alternately.

When stacking the units vertically.

When stacking the units horizontally.

• Panel thickness 1 to 6 mm
• X=48 x (number of amplifiers) -3

45 mm

X mm

+ 0.6
− 0

Min. 85 mm

45 mm

45 mm

+ 0.6

− 0

+ 0.6

− 0

Panel mounting bracket

Panel

Sensor amplifier

Front protection cover