Auto peak hold, Wvq2, 2 basic settings and advanced settings – KEYENCE IL Series User Manual

Page 75: Trigger level setting screen, Il-e, Setting v ar iou s f unct ions

Advertising
background image

4-2 Basic Settings and Advanced Settings

4-21

IL-E

4

Setting V

ar

iou

s F
unct

ions

Auto peak hold

When the internal measurement value (R.V.) goes beyond the specified trigger level, the
sampling begins. When it falls below the trigger level, the sampling finishes. When the
sampling finishes, the maximum internal measurement value (R.V.) during the sampling
period is held as a judgment value (P.V.).
The external input is not required.

*1

"11. External Input" (page 4-30)

*2 After the power is turned on or reset is input, the judgment value (P.V.) is [-----] until the

judgment value (P.V.) is first held.

*3 While the timing input is ON, the sampling does not start. If the sampling is already in

process, it continues.

*4 The main unit (IL-1000/IL-1500) displays the calculation value (CALC value) when the

calculation function is used.

“4-3 Calculation Function” (page 4-42)

„

Trigger level setting screen

When the auto peak hold is set, the display goes to the trigger level setting screen.

Press S / T button on the trigger level setting screen to specify the trigger level.
IL-S025/IL-030/IL-S065/IL-065/IL-100

IL-300/IL-600

IL-2000

Reference

• The operation by the timing input is the same regardless of the "7. Timing

Input" (page 4-23) setting.

• After the sampling starts, if the internal measurement value (R.V.)

becomes "-----" before the sampling falls below the specified trigger

level, the sampling is automatically finished and the maximized value

during the sampling period is held as a judgment value (P.V.).

Display value

Time

Timing Input

Trigger level

Hysteresis

ON

OFF

Power ON or
Reset input *

1

*

3

*

2

Judgment value (P.V.)
Internal measurement value (R.V.)*

4

Item

Setting range

Default value

Trigger level

-99.999 to 99.999

1.000

Item

Setting range

Default value

Trigger level

-999.99 to 999.99

10.00

Item

Setting range

Default value

Trigger level

-9999.9 to 9999.9

100.0



LASER

BANK

0

1

2

3

HI

GO

LO

R.V. ANALOG

HI SHIFT

ZERO SHIFT

TIMING

LO

VT)

HOLD CALC CHECK

#WVQ2

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

 *.&

GO

HOLD

CALC

CHECK

QHH

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

 &.;

GO

HOLD

CALC

CHECK

6. Hold function

Trigger level setting screen

8. Delay timer

[MODE]
or X

[MODE]
or X

Advertising