Power/input-output cable – KEYENCE IL Series User Manual

Page 27

Advertising
background image

2-1 Mounting and Wiring the Sensor Amplifier

2-7

IL-E

2

Installation and C

onnection

Power/Input-output cable

"Output Circuit Diagram" (page 5-5)

*1 IL-1050/IL-1550 (expansion units) do not have brown, blue or light blue wires.

Power is supplied to the expansion units through IL-1000/IL-1500 (main unit).

*2 The analog output can be set to any of the following options either "When the power is

turned on for the first time" or "When performing the initial reset".

Not used (OFF)

0 to 5 V

-5 to 5 V

1 to 5 V

4 to 20 mA

"3-1 Operation When the Power is Turned on for the First Time" (page 3-2)
"3-3 Initial Reset (Initialize)" (page 3-8)

*3 The external input can be selected among the following in addition to the above.

Bank A input

Bank B input

Laser emission stop input

Not used (OFF)

Gain input only be selected for external input 4.

"11. External Input" (page 4-30)

*4 When expanding to six or more units, use a power supply that provides 20 to 30 V.

Brown

Blue

Black

White

Gray

Light blue

Orange

Shield

Pink

Yellow

Pink/Purple

Purple

Green

10 to 30 VDC

0 V

HIGH judgment output

LOW judgment output

GO judgment output

Analog output +

Analog output GND

External input 1 (Zero shift input)

External input 2 (Reset input)

External input 3 (Timing input)

External Input 4 (Not in use)

Alarm output

*1

*1

*1

*2

*2

*3

*3

*3

*3