4-2 Basic Settings and Advanced Settings

4-34

4

Setting V

ar

iou

s F
unct

ions

IL-E

Bank A input/Bank B input

By combining ON/OFF setting of bank A input and bank B input, you can switch the banks.

“3-6 Bank Function (Registering Multiple Tolerance Setting Values)” (page 3-20)
"12. Bank Switching Method" (page 4-35)

„

Timing chart

„

Minimum Input Time

ON time: 20 ms
OFF time: 20 ms

Reference

When the judgment value (P.V.) is held using the hold function, the judgment
value (P.V.) remains held even if ON/OFF for bank A input or bank B input is
switched. However, the judgment output changes according to the setting
value set for the new bank.

"6. Hold Function" (page 4-15)

Judgment value
(P.V.) judgment
output

Max. 8 ms

Max. 20 ms

Max. 20 ms

Min. 20 ms

ON

OFF

Bank A input

ON

OFF

Bank B input

Max. 20 ms

Bank 1

Bank 2

Bank 3

Bank 0

In this example, after 8 ms have passed, Bank A
and Bank B are judged as OFF and operation at
Bank 0 may be performed during a certain period.