External input, External input -30, External input setting screen – KEYENCE IL Series User Manual
Page 84: 5jk(v, Tgugv, 6k/p), 2 basic settings and advanced settings

4-2 Basic Settings and Advanced Settings
4-30
4
Setting V
ar
iou
s F
unct
ions
IL-E
You can select functions to be assigned to four external inputs (External input 1 to 4).
"Power/Input-output cable" (page 2-7)
External input setting screen
When the user setting is set, each function of the external input 1 to 4 can be set.
Functions that can be set differ for each external input. (When the default is set, these four
screens are skipped.)
Press S / T button on each setting screen to specify functions.
11. External Input
KP
External Input
Description
Default value
Default setting
Functions for the external inputs remain the same as the
factory default setting.
c
User setting
Functions for the external inputs are changed from the
factory default setting.
External Input 1 (Pink wire)
External Input 2 (Yellow wire)
Setting
value
Description
Default
value
Setting
value
Description
Default
value
shift
Zero shift input
c
reset
Reset input
c
bnK-a
Bank A input
bnK-a
Bank A input
bnK-b
Bank B input
bnK-b
Bank B input
L-stp
Laser emission stop input
L-stp
Laser emission stop input
off
Not use
off
Not use
External input 3 (Pink/Purple wire)
External Input 4 (Purple wire)
Setting
value
Description
Default
value
Setting
value
Description
Default
value
tiMng
Timing Input
c
off
Not use
c
bnK-a
Bank A input
bnK-a
Bank A input
bnK-b
Bank B input
bnK-b
Bank B input
L-off
Laser emission stop input
L-stp
Laser emission stop input
off
Not use
Reference
When the same function is selected for multiple external inputs, if any are
ON, ON (OR operation) works.
75T
LASER
BANK
0
1
2
3
HI
GO
LO
R.V. ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
KP
HOLD CALC CHECK
5JK(V
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
KP
GO
HOLD
CALC
CHECK
TGUGV
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
KP
GO
HOLD
CALC
CHECK
6K/P)
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
KP
GO
HOLD
CALC
CHECK
Q((
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
KP
GO
HOLD
CALC
CHECK
DVP
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
DP-
GO
HOLD
CALC
CHECK
11. External Input
External input 1 setting screen
External input 2 setting screen
[MODE]
or X
[MODE]
or X
[MODE]
or X
External input 3 setting screen
External input 4 setting screen
12. Bank switching method
[MODE]
or X
[MODE]
or X