4-2 Basic Settings and Advanced Settings

4-16

4

Setting V

ar

iou

s F
unct

ions

IL-E

Sample hold

When the timing input is turned ON, the judgment value (P.V.) is held.

„

When "Level" is set for "7. Timing Input" (page 4-23)

The judgment value (P.V.) is held only while the timing input is ON.

*1 The main unit (IL-1000/IL-1500) displays the calculation value (CALC value) when the

calculation function is used.

“4-3 Calculation Function” (page 4-42)

„

When "Edge" is set for "7. Timing Input" (page 4-23)

The judgment value (P.V.) is held while the timing input is ON.

*1

"11. External Input" (page 4-30)

*2 The main unit (IL-1000/IL-1500) displays the calculation value (CALC value) when the

calculation function is used.

“4-3 Calculation Function” (page 4-42)

Display value

Time

Judgment value (P.V.)
Internal measurement value (R.V.)*

1

Timing Input ON

OFF

Display value

Time

Judgment value (P.V.)
Internal measurement value (R.V.)*

2

Timing Input ON

OFF

Power ON or
Reset input *

1

After the power is turned on or reset is input, the judgment value (P.V.) is
[- - - - -] until the timing input is first turned ON.