Settings registered with the bank, How to switch the bank – KEYENCE IL Series User Manual

Page 52

Advertising
background image

3-20

IL-E

3

Basic Oper

ations

3-6

Bank Function (Registering Multiple Tolerance Setting Values)

Using the bank function, you can register up to four patterns of specified tolerance settings.
By using the bank function, each setting item registered beforehand can be switched easily.

*1 The shifted amount when the internal measurement value (R.V.) is shifted using the

zero shift function is saved in each bank.
(example) Suppose the zero shift function is used with bank 0, then the unit is switched

to bank 1, and while in bank 1, the zero shift is used again. If the unit is
switched back to bank 0, the zero shift associated with bank 0 is recalled.

The bank switching method can be done in any of the 3 fashions below.
• Front panel commands on the amplifier.
• Use the external inputs (Bank A input, Bank B input)*
• Send command from DL-RS1A (Refer to DL-RS1A User's Manual for details)
* If the bank switching method is set to external input, and bank A input or bank B input is

set for the external input, the bank can be switched with the external input.

"11. External Input" (page 4-30)
"12. Bank Switching Method" (page 4-35)

Settings Registered with the Bank

Settings

Reference page

HIGH side setting value

"3-4 Setting the Tolerance Setting Value" (page 3-
10)

LOW side setting value

Shift target value

*1

"3-5 Zero Shift Function (Shifting the Internal

Measurement Value (R.V.))" (page 3-18)

Analog output free range upper

limit/lower limit

"10. Analog Output Scaling" (page 4-27)

How to Switch the Bank

Advertising