Hysteresis, Hysteresis -26 – KEYENCE IL Series User Manual
Page 80
4-2 Basic Settings and Advanced Settings
4-26
4
Setting V
ar
iou
s F
unct
ions
IL-E
The hysteresis for the tolerance setting value is set.
If the judgment value (P.V.) fluctuates due to the vibration of the object, etc. and the
judgment output repeats ON/OFF, increasing the hysteresis value stabilizes ON/OFF.
“3-4 Setting the Tolerance Setting Value” (page 3-10)
IL-S025/IL-030/IL-S065/IL-065/IL-100
IL-300/IL-600
IL-2000
9. Hysteresis
*;5
Item
Setting range
Default value
Hysteresis
0.000 to 99.999
0.000
Item
Setting range
Default value
Hysteresis
0.00 to 999.99
0.00
Item
Setting range
Default value
Hysteresis
0.0 to 9999.9
0.0
Reference
The above is the timing chart when the output state of judgment output is
Normally Open (default value). ON/OFF is reversed for Normally Close.
Time
Hysteresis
Hysteresis
Judgment value (P.V.)
HIGH side setting value
LOW side setting value
ON
OFF
ON
OFF
ON
OFF
HIGH judgment output
GO judgment output
LOW judgment output