4-2 Basic Settings and Advanced Settings
4-33
IL-E
4
Setting V
ar
iou
s F
unct
ions
z
When Peak hold, Bottom hold or Peak-to-peak hold is set
"7. Timing Input" (page 4-23) setting: "Level"
"7. Timing Input" (page 4-23) setting: "Edge"
z
When Auto peak hold or Auto bottom hold is set
Minimum Input Time
ON time: 2 ms
OFF time: 2 ms
Max. 2 ms
Max. 2 ms
Min. 2 ms
Min. 2 ms
ON
OFF
Max. 2 ms
No sampling
No sampling
Sampling period
Previous result
Judgment value
(P.V.) judgment
output
Timing Input
Judgment value
(P.V.) judgment
output
Max. 2 ms
Max. 2 ms
Min. 2 ms
Min. 2 ms
ON
OFF
Timing Input
Sampling period 1
Sampling period 1 result
Sampling period 2 result
Previous result
Sampling period 2
Sampling period 3
Max. 2 ms
Max. 2 ms
Max. 2 ms
Min. 2 ms
Min. 2 ms
ON
OFF
Timing Input
Sampling does not start
Sampling starts