4-2 Basic Settings and Advanced Settings
4-40
4
Setting V
ar
iou
s F
unct
ions
IL-E
When no buttons are pressed for more than one minute, the power saving function is
activated with the sensor amplifier.
The power saving function is activated as soon as the setting is complete. The normal
display is restored by pressing any of the buttons.
*1 Only one segment (horizontal bar in the center) on the main display
(upper) flashes, moving in order on the display from right to left. Also,
the sub display indicator turns off.
The display status of the sensor head is set.
16. Power Saving Function
'EQ
Power save function
Sensor Amplifier
Default
value
OFF
Normally ON
c
Half
Animation display
*1
All
All OFF
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
Move to the left
17. Head Display Mode
*'&
Head display mode
Item
Description
Default
value
Normal display mode
(1) Reference
distance
indicator
Lights near the center of the
measurement range.
c
(2) Analog
range
indicator
Lights when in the range of
the analog output.
*1
(3) Laser
radiation
emission indicator
Lights while the laser is
being emitted, and blinks
when stopped.
Judgment status
display mode
(1) Reference
distance
indicator
During GO judgment: Green
LED turns ON
*2
During HI, LOW, Err: Red
LED turns ON
*2
Judgment standby status:
OFF
(2) Analog
range
indicator
Always OFF
(3) Laser
radiation
emission indicator
Lights while the laser is
being emitted, and blinks
when stopped.
OFF
(1) Reference
distance
indicator
Always OFF
(2) Analog
range
indicator
Always OFF
(3) Laser
radiation
emission indicator
Lights while the laser is
being emitted, and blinks
when stopped.