Timing input, Delay timer, Timing input -23 8. delay timer -23 – KEYENCE IL Series User Manual

Page 77: Regardless of the "7. timing, Of the "7. timing

Advertising
background image

4-2 Basic Settings and Advanced Settings

4-23

IL-E

4

Setting V

ar

iou

s F
unct

ions

IL-2000

The external input (timing input) operation used for "6. Hold Function" (page 4-15) is set.
If "Auto peak hold" or "Auto bottom hold" is set, this item is skipped.

For details, refer to the "6. Hold Function" (page 4-15).

The delay timer for the judgment output is set.
There are three judgment outputs as below.
• HIGH judgment output (Black wire)
• GO judgment output (Gray wire)
• LOW judgment output (White wire)
The judgment output is turned ON/OFF according to the tolerance setting value and the
output state settings.

“3-4 Setting the Tolerance Setting Value” (page 3-10)
"5. Output State" (page 4-14)

Item

Setting range

Default value

Trigger level

-9999.9 to 9999.9

100.0

Reference

The hysteresis presents the same value as the one set for "9. Hysteresis"
(page 4-26).

7. Timing Input

 6K/

Item

Setting range

Default value

Timing Input

LeveL

(Level), edGe (Edge)

LeveL

8. Delay Timer

 &.;

Delay Timer

Description

Default

value

Delay timer off

The delay timer is not used.

c

ON-delay timer

Time required to change the GO judgment output
operation from OFF to ON is delayed for specified time set
on the timer.

"ON-delay timer" (page 4-24)

OFF-delay timer

Time required to change the GO judgment output
operation from ON to OFF is delayed for specified time set
on the timer.

"OFF-delay timer" (page 4-25)

1-shot timer

When GO judgment output is turned ON, if the specified
time elapses, GO judgment output is automatically turned
OFF.

"1-shot timer" (page 4-25)

Advertising