3 initial reset (initialize), 3 initial reset (initialize) -8, Initial reset (initialize) -8 – KEYENCE IL Series User Manual

Page 40: Initial reset (initialize), T'5'v, Il-e, Basic oper ations, Analog output scaling" (page 4-27), Mode] button, Point

Advertising
background image

3-8

IL-E

3

Basic Oper

ations

3-3

Initial Reset (Initialize)

When initial reset is performed, all settings, excluding the calibration function, are initialized.
The judgment output's polarity and analog output setting can be changed with the same operation.

Main screen

1

While pressing the [MODE] button on the main screen,
press the [SET] button 5 times.

[reset] is displayed on the main display (upper level).

While pressing the
[MODE] button,
press the [SET]
button 5 times.

2

Press S/T button to select [yes] and press the
[MODE] button.

If [no] is selected at this point, only the output polarity and analog
output settings can be changed without performing the initial reset.

[MODE] button

3

Press S/T button to select the output polarity and
press the [MODE] button.

[MODE] button

4

Press S/T button to select the analog output and
press the [MODE] button. (only for IL-1000 / IL-1500
only)

"10. Analog Output Scaling" (page 4-27)

[MODE] button

5

After the initialization is complete, [end] blinks several
times on the sub display and the main screen is restored.

Point

If the calculation function is used, perform the initial reset for the
main unit first.

Reference

• When buttons other than the S/T button and [MODE] button are pressed

during the initial reset procedure, the initial reset is canceled and the
screen in step 2 is restored.

• When you attempt to initialize the unit while the key

lock function is set, the screen shown on the right
appears and the initialization fails.
Cancel the key lock before attempting to initialize the unit.

"3-7 Key Lock Function" (page 3-21)



LASER

BANK

0

1

2

3

HI

GO

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT



HOLD

CALC

CHECK

;GU

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

T'5'V

GO

HOLD

CALC

CHECK

Performing the initial reset

PRP

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

QWV

GO

HOLD

CALC

CHECK

Output polarity

Setting value

Description

npn

NPN output

pnp

PNP output

QHH

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

#P.)

GO

HOLD

CALC

CHECK

Analog output

Setting value

Description

off

Not output

0-5 u

Analog output after the judgment value is converted to the range from 0 to 5 V.

-5-5 u

Analog output after the judgment value is converted to the range from -5 to 5 V.

1-5 u

Analog output after the judgment value is converted to the range from 1 to 5 V.

aMpr

Analog output after the judgment value is converted to the range from 4 to 20 mA.

'PF

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

T'5'V

GO

HOLD

CALC

CHECK

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

.QE

GO

HOLD

CALC

CHECK

Advertising