KEYENCE IL Series User Manual

Page 72

Advertising
background image

4-2 Basic Settings and Advanced Settings

4-18

4

Setting V

ar

iou

s F
unct

ions

IL-E

Bottom hold

The minimum value of the specified period (sampling period) is held as a judgment value (P.V.).

„

When "Level" is set for "7. Timing Input" (page 4-23)

The sampling period is from the falling edge of the timing input to the next rising edge. On the
rising edge, the internal measurement value (R.V.) minimized during the sampling period is held
as a judgment value. When the timing input is turned OFF, the next sampling period begins.

*1

"11. External Input" (page 4-30)

*2 The main unit (IL-1000/IL-1500) displays the calculation value (CALC value) when the

calculation function is used.

“4-3 Calculation Function” (page 4-42)

*3 If the R.V. value (or CALC value) causes an alarm even once during the sampling period, the

hold results will be "-----".

„

When "Edge" is set for "7. Timing Input" (page 4-23)

The sampling period is from the rising edge of the timing input to the next rising edge of the
timing input. On the rising edge, the internal measurement value (R.V.) minimized during
the sampling period is held as a judgment value. When the timing input is turned ON, the
next sampling period has already begun.

Display value

Time

Timing Input

Sampling period

Sampling period

Sampling period

ON

OFF

Power ON or
Reset input *

1

After the power is turned on or reset is input, the judgment value (P.V.) is
[- - - - -] until the timing input is first turned ON.

Judgment value (P.V.)
Internal measurement value (R.V.)*

2

Display value

Time

Timing Input

Sampling period

Sampling period

Sampling period

ON

OFF

Power ON or
Reset input *

1

After the power is turned on or reset is input, the judgment value (P.V.) is
[- - - - -] until the timing input is first turned ON.

Judgment value (P.V.)
Internal measurement value (R.V.)*

2

Advertising