2-2 Connecting and Mounting the Sensor Head

2-9

IL-E

2

Installation and C

onnection

Connecting the sensor head and amplifier

1

Attach the sensor head connection cables to the sensor head cable

2

Attach the sensor head connection cable to the amplifier connector.

Connection and Wiring

Point

Tighten the connectors securely by hand.
If they are loose, the IP67 environmental resistance rating
cannot be guaranteed.

Remove the lock cover of the connector and
insert it into the connectors of amplifier until a
clicking sound is heard.

DIN rail mount type
(IL-1000/IL-1050)

Panel mount type
(IL-1500/IL-1550)

(1) Align the arrow position of the connector to insert.
(2) Rotate the connector screw to tighten.

* For the IL-2000, the direct connector will come out

directly from the sensor head, so there is no arrow.