4-2 Basic Settings and Advanced Settings

4-14

4

Setting V

ar

iou

s F
unct

ions

IL-E

According to the judgment value (P.V.), set the output state (N.O./N.C.) of judgment output
ON/OFF and edge check output.

There are three judgment outputs as below.
• HIGH judgment output (Black wire)
• GO judgment output (Gray wire)
• LOW judgment output (White wire)
The judgment output is turned ON/OFF as below according to the tolerance setting value.

“3-4 Setting the Tolerance Setting Value” (page 3-10)

When Normally Open is set

When Normally Closed is set

*1

"Error Displays and Corrective Actions" (page A-4)

*2 When the judgment value (P.V.) is "-----".

5. Output State

 QWV

Item

Setting range

Default value

Output state

no

(Normally Open), nC (Normally Closed)

no

Judgment

Judgment output

HIGH

GO

LOW

HIGH

ON

OFF

OFF

GO

OFF

ON

OFF

LOW

OFF

OFF

ON

Error

*1

ON

OFF

ON

"-----"

*2

OFF

OFF

OFF

Judgment

Judgment output

HIGH

GO

LOW

HIGH

OFF

ON

ON

GO

ON

OFF

ON

LOW

ON

ON

OFF

Error

*1

OFF

ON

OFF

"-----"

*2

ON

ON

ON

Reference

Regardless of the output state setting, the judgment indicator on the sensor
amplifier interlocks the judgment output when Normally Open is set.

“3-4 Setting the Tolerance Setting Value” (page 3-10)

The following is the default state of the judgment indicator. The lighting
status can be changed in the items for "18. Display Color".

"18. Display Color" (page 4-41)

Judgment

Judgment output

HIGH

GO

LOW

HIGH

Red

OFF

OFF

GO

OFF

Green

OFF

LOW

OFF

OFF

Red

Error

Red

OFF

Red

"-----"

OFF

OFF

OFF