2.4 Instruction Details

1

2

3-89

Chapter 2 Instructions

MC:

Master Control

MCR: Master Control

Reset

Selects ON/OFF status of relay coils, timers,
or counters set before MCR instruction.

Used in pairs with MC instruction to end the
execution of MC instruction.

LDB

4

ANB

5

ANL

2

ANL

2

MCR

MC

FUN

FUN

0000

MC

MCR

0001

0500

0501

Example

Coding

Description

When 0000 is OFF, both 0500 and 0501 do not turn ON, even if 0001 is turned
ON.

When 0000 is ON, 0500 turns ON and 0501 turns OFF as soon as 0001 is turned
ON.

Regard the function of MC-MCR instructions as "power switch" or "main switch".

When the input relay for MC is OFF, the instructions entered between MC and
MCR instructions function as follows:

Note: MC-MCR instructions cannot be used in the following configuration.

1. Nesting

2. Improper combination with STP-STE

instructions

➮ "STP, STE instructions" (p. 3-114)

Operands

Key operation

Line No.

Instruction

Operand

0000

LD

0000

0001

MC

0002

LD

0001

0003

OUT

0500

0004

OUB

0501

0005

MCR

MC

MC

MCR

MCR

STP

x x x x

MC

STE

MCR

FUN

FUN

LDB

4

ANB

5

ANL

2

ANL

2

ENT

R-SRCH

ENT

R-SRCH

ENT

R-SRCH

ENT

R-SRCH

:

:

MC / MCR

Instructions

Function

OUT and OUB

Corresponding relay is OFF

TMR, TMH, and TMS

Timer is reset

C, SFT, KEEP, SET, RES, and CTH

Previous status is retained

Other instructions such as TMIN

Instruction is not executed.

KVNKA Chap 02_4aP.p65

08.3.11, 11:58 AM

89