6.3 Positioning Control

KV

-300

KV-10/80

3-298

6

Chapter 6 Interrupts, High-speed Counters, Positioning Control

Set value error code
Automatically writes an error code (11 to 17) into DM9407 when a parameter setting
error is found at startup.

Corrective action for error code 16
Error code 16 is issued when the output pulse count during acceleration/decelera-
tion time exceeds other values calculated from the preset parameters.
To recover from the error, the following corrective actions are available.

Change the run frequency and/ or the acceleration/ deceleration time according
to the following expression.

Corrective action for error code FFFF (-1)

Reduce run frequency and start frequency.

Reduce accelleration/ deccelleration time.

Start frequency (Hz)
Sets a start frequency (speed) to start the motor rotation smoothly during positioning
control.

The KV-300 CPU outputs clock pulses at the specified frequency.

Run frequency (Hz)
Sets the motor frequency (speed) during positioning control. The KV-300 CPU
outputs clock pulses at the specified frequency.

Note: When the start frequency equals the run frequency, the system operates as
shown in the following chart.

Here, the acceleration/deceleration time is ignored. The output count should be less
than 65535.

0

Preset frequency

Code

Error description

Corrective action

11

Start frequency is below allowable

Adjust start frequency to within allow-

range.

able range (153 to 50000).

12

Run frequency is below allowable

Adjust run frequency to within allow-

range.

able range (153 to 50000).

13

Run/start frequency exceeds allow-

Adjust run/start frequency to within

able range.

allowable range (153 to 50000).

14

Start frequency is greater than run

Reduce start frequency to less than

frequency.

run frequency.

15

Acceleration/deceleration time

Adjust acceleration/deceleration time

exceeds allowable range.

to within allowable range (0 to 4096).

16

Too many pulses are output during

Change the parameters.

acceleration/deceleration time.

17

Too few pulses are output during

Set 2 or more as value for output

acceleration/deceleration time.

pulse count.

FFFF

Other calculation error

Change the parameters.

65535

Run frequency

x Pulse change cycle x 65535

1000