2.4 Instruction Details

3-58

2

Chapter 2 Instructions

AND: And

ANB: And Bar

Connects N.O. contact in series with
previous contact.

Connects N.C. contact in series with
previous contact.

AND

8

ANB

5

nnnn

nnnn

Example

Coding

To turn ON 0503, 0002 must be ON, 0003 OFF, and 0004 ON at the same time. The
AND and ANB instructions are used when two or more conditions (in this case,
0002: ON, 0003: OFF, 0004: ON) must be satisfied at the same time.

Description

As many contacts as desired can be connected in series provided these contacts
are used in the same program.

As OUT 0503 shown in the above example, when an AND or ANB instruction is
used immediately after an OUT instruction to connect the other relay via a
contact (0004 in the example), the AND or ANB can be used as many times as
desired, provided the program syntax is correct.

The following two circuits operate in the same manner, but the coding for these
circuits are different.

Coding

Coding

0000

0500

0002

0001

0004

0003

0501

0502

0503

Line No.

Instruction

Operand

0000

LD

0000

0001

AND

0001

0002

OUT

0500

0003

LD

0002

0004

ANB

0003

0005

OUT

0501

0006

OUT

0502

0007

AND

0004

0008

OUT

0503

0000

0001

0501

0500

Line No.

Instruction

Operand

0000

LD

0000

0001

OUT

0500

0002

AND

0001

0003

OUT

0501

Line No.

Instruction

Operand

0000

LD

0000

0001

MPS

0002

AND

0001

0003

OUT

0501

0004

MPP

0005

OUT

0500

0000

0001

0501

0500

:

:

AND / ANB

➮ "MPS instruction" (p. 3-103)

➮ "MPP instruction" (p. 3-103)