5.3 Examples of Using the Positioning Control Function

Visual KV

Series

1

5

Chapter 5 Positioning Control

3-261

Ladder example of automatic operation (palletizing operation)

A palletizing operation is automatically performed.
The machine moves to a target coordinate, then returns to the start position. Next,
the machine moves to a position further away than the target coordinate, then again
returns to the start position. Such an operation is realized using repetitious and
return movements. This type of operation is suitable for, for example, a job where
workpieces to be supplied are located in one position and a moving body picks up
the workpieces and positions them little by little at a certain interval.

When start signal 0000 is set to ON, a moving body moves to point 1, returns to the
start position, moves to point 2, and then returns to the start position again. After-
wards, the moving body moves to point 3, then returns to the start position, output
05000 remains ON for 3 seconds, and then the operation is finished.

Program example

5000

0

5000

500

500

Speed (Hz)

Point 3: 14,000

Point 1: 10,000

Coordinate (pulses)
Point 2: 12,000

#00000

DW

#03000

DW

#05000

DW

#00500

DW

DM1485

DM1482

DM1481

DM1480

0001

0002

0003

0004

0005

0006

0007

0008

0009

0010

0011

0012

0013

0014

0015

0016

0017

0018

0019

1000

SET

0000

#10000

DM1484

DW

2310

1001

JMP

1000

STG

0503

SET

#12000

DM1484

DW

2310

1003

JMP

1002

STG

0503

SET

1100

2310

1002

JMP

1001

STG

2309

1100

1102

2310

1004

JMP

1003

STG

0503

RES

2309

1102

1104

2310

1006

JMP

1005

STG

0503

RES

2309

1104

1101

2309

1101

2310

1005

JMP

1004

STG

0503

SET

1103

2309

1103

1201

2309

1201

1200

2309

1200

1203

2309

1203

1202

2309

1202

1204

2309

1204

END

ENDH

0500

#00030

T000

T000

1105

ENDS

1006

STG

2309

1105

#14000

DM1484

DW

0503

RES

Ladder for automatic operation

Point 1: 10,000

Point 2: 12,000

Point 3: 14,000

Moves to point 1.

Returns from point 1.

Moves to point 2.

Returns from point 2

Moves to point 3.

Returns from point 3.

When operation has completed, output 500 remains ON for 3 seconds.