8.2 Details

3-327

1

8

Chapter 8 Programming Examples

On-delay circuit
Output relay 0500 turns ON in a specified time after input relay 0000 turns ON.
When input relay 0000 turns OFF, output relay 0500 also turns OFF.

Timing diagram

Ladder diagram

Coding

Flicker circuit
Output relay 0500 turns ON and OFF repeatedly while input relay 0000 is ON.

Timing diagram

Ladder diagram

Coding

Accumulator timer (Remains ON in case of power failure)
Counts special utility relay 2006 (1-s clock pulse) for 3600 s at C001 and inputs the
count value to C002. Accumulates the count for 10000 hours and retains the current
count value even when power failure occurs or power is OFF.
Input relay 0000
Reset relay 0001
(Resolution is 1 s at 2006.)

Ladder diagram

Coding

0500

0000

2s

1s

0000

#00020

T000

0500

T000

2-s timer

0500

0000

2s

1s

1s

2s

0000

#00020

T000

T000

2-s timer

0500

#00010

T001

T001

1-s timer

Line No.

Instruction

Operand

0000

LD

0000

0001

TMR

000 #00020

0002

LD

T000

0003

OUT

0500

Line No.

Instruction

Operand

0000

LD

0000

0001

ANB

T001

0002

TMR

000 #00020

0003

LD

T000

0004

TMR

001 #00010

0005

OUT

0500

0000

#03600

C001

C001

3600-s counter

C001

1-s pulse

0001

#10000

C002

10000-s counter

1000

1000

2006

Line No. Instruction

Operand

0000

LD

0000

0001

ANB

C001

0002

C

001 #03600 2006

0003

LD

C001

0004

OUT

1000

0005

LDB

0001

0006

C

002 #10000 1000