5.3 Examples of Using the Positioning Control Function

Visual KV

Series

5

Chapter 5 Positioning Control

3-260

Ladder example of the jog operation

The jog operation is performed.

While input 0000 is ON, the machine continues to move in the CW direction.
When input 0000 turns OFF, the machine decelerates and stops.

While input 0001 is ON, the machine continues to move in the CCW direction.

When input 0001 turns OFF, the machine decelerates and stops.

Program example

1000

500

Speed (Hz)

CW direction

CCW direction

Coordinate (pulses)

Input 0000
(CW direction)

Input 0001
(CCW direction)

1000
DIFU

0000

0001

#65535

DW

#65535

DW

#01000

DW

#02000

DW

#00500

DM1484

DM1485

DM1482

DM1481

DM1480

DW

1000

1100

1001

0503

SET

2310

2308

END

ENDH

0001

2309

0000

1001
DIFU

1100
DIFU

0503

RES

0000

2309

0001

0001

0002

0003

0004

0005

0006

0007