Chapter 1 Programming

Relay 2008: Remains ON during only one scan when operation is started.

This relay can be used for an initial reset at the start of operation.
After one scan, this relay remains OFF.

Relay 2813: Sets the input time constant of the CPU.

While relay 2813 remains ON, the input time constant of a basic unit can be set
using the value of DM1940.

When operation is started, this relay sets all internal
utility relays used by the SFT instruction to OFF.

0000

1000

SFT

D

CLK

RES

2008

1100

1100

#00000

LDA

DM0000

STA

2008

When operation is started, this relay returns the current
value of DM0000 to 0.