2.4 Instruction Details
1
2
3-71
Chapter 2 Instructions
■ On-delay circuit
Output relay 0500 turns ON in a specified time after input relay 0000 turns ON.
When input relay 0000 turns OFF, output relay 0500 also turns OFF.
Timing diagram
Coding
■ Flicker circuit
Output relay 0500 turns ON and OFF repeatedly while input relay 0000 is ON.
Timing diagram
Coding
0000
T000
0500
#00020
T000
OFF
ON
ON
0000
0500
Line No.
Instruction
Operand
0000
LD
0000
0001
TMR
000 #00020
0002
LD
T000
0003
OUT
0500
0000
T001
T000
0500
#00020
T000
#00010
T001
2 sec.
2 sec.
1 sec.
OFF
ON
ON
ON
0000
0500
ON
Line No.
Instruction
Operand
0000
LD
0000
0001
ANB
T001
0002
TMR
000 #00020
0003
LD
T000
0004
AMR
001 #00010
0005
OUT
0500
2 s
1 s
2 s 1 s 2 s 1 s 2 s 1 s
TMR
KVNKA Chap 02_4aP.p65
08.3.11, 11:58 AM
71