2.4 Instruction Details

3-102

2

Chapter 2 Instructions

Example

Coding

Description

When input relay 0000 turns ON, 0500, 0501, 0502, and 0503 turn ON.

When input relay 0000 turns OFF, 0500, 0501, 0502, and 0503 turn OFF.

The CON instruction is used to connect instructions after output instructions
when the extended ladder is used.

When the LADDER BUILDER for KV programming support software is used, the
CON instruction is automatically converted into a mnemonic and entered in the
ladder diagram by just writing a connection line.

The CON instruction does not affect the scan time.

➮ Refer to "1.5 Extended Ladder Diagrams" (p. 3-29) for details of eetecded ladders.

Operands

Key operation

CON: Connect

Represents series connection of output
instruction with another instruction.

RES

0

ORB

6

FUN

0000

0503

0502

0501

0500

CON

CON

CON

Line No.

Instruction

Operand

0000

LD

0000

0001

OUT

0500

0002

CON

0003

OUT

0501

0004

CON

0005

OUT

0502

0006

CON

0007

OUT

0503

RES

0

ORB

6

FUN

ENT

R-SRCH

ENT

R-SRCH

:

CON