5.3 Examples of Using the Positioning Control Function

Visual KV

Series

5

Chapter 5 Positioning Control

3-258

5.3

Examples of Using the Positioning
Control Function

This section describes examples of connecting a stepping motor driver and perform-
ing ramp-up/down control using the positioning control function of the Visual KV
Series.

5.3.1

Connection Example

Connect the Visual KV Series and stepping motor driver as shown below.
This example is only for reference. For details, refer to the instruction manual for the
stepping motor driver.
Set the pulse input type of the stepping motor driver to "1 pulse input type".

When using a 24 VDC power supply, be sure to use the outputs with current limiting
resistors (R500, R501, and R502) or use the normal outputs with external current limiting
resistors.

5.3.2

Tips

When using a servo motor, also refer to the connection example above. However,
I/O control dedicated to a servo motor such as servo ON is also required.

CW

Visual KV

24 VDC

FG

+

+

+

5 VDC*

+

CCW

0 0 0 2

0 0 0 1

0 0 0 0

R 0 5 0 2

C O M

C O M

R 0 5 0 3

Emergency stop

Stop

Start

Stepping motor driver

Twisted pair cable

(pulse)

(rotation
direction)

Stepping motor