6.3 Positioning Control

KV

-300

KV-10/80

3-296

6

Chapter 6 Interrupts, High-speed Counters, Positioning Control

6.3

Positioning Control

6.3.1

Positioning Control (Ramp-up/down Control)

Outline of positioning control

The KV-300 CPU outputs clock pulses, independent of scan time, directly through
output relay 0500 or 0501. When the clock pulse frequency, output pulse count, and
acceleration/deceleration time are set to the data memory addresses in advance,
the KV-300 CPU automatically performs ramp-up/down control. Output frequency
can be set within the range of 153 Hz to 50000 Hz.

With this function, ramp-up/down control over stepper motors and AC servo motors
(pulse input type) becomes possible.
The following section describes setting and application of positioning control
parameters.

Acceleration time

Deceleration time

Time (ms)

Frequency (Hz)

Operation

Start

Output pulse count

Stepping motor
/servo motor

Motor driver

Clock pulse

Rotation direction

Lo : CW
Hi : CCW

KV-300

0500
0501

0502
0503

KVNKA Chap 06.p65

08.3.11, 0:10 PM

296