Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 100

Advertising
background image

96

xL Regional Settings Guide

21-3609E rev1.0

R001

È08 Keypad Selections

N America

10 (1 min)

European

10 (1 min)

U.K. ACPO

10 (1 min)

Aus/NZ

10 (1 min)

China/H.K.

10 (1 min)

Netherlands 10 (1 min)
Switzerland

10 (1 min)

Challenged Door
Held Open Time

Delay Table

How long the door can be held
open without causing an alarm
after a physically-challenged
user enters. Whether or not the
'Challenged' door held open time
applies is based on the
'Challenged' setting for the user.
For details, refer to U001È02
(“Physically Challenged“
setting).

France

10 (1 min)

N America

14 (5 min)

European

14 (5 min)

U.K. ACPO

14 (5 min)

Aus/NZ

14 (5 min)

China/H.K.

14 (5 min)

Netherlands 14 (5 min)
Switzerland

14 (5 min)

Auxiliary Relay
Output Time

Delay Table

How long the door can be held
open after access is granted
without causing an alarm.

France

14 (5 min)

N America

0

European 0
U.K. ACPO

0

Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0

Auxiliary Input Mode

0=None, 1=Mag Lock Bond
Sense, 2=Challenged RTE,
3= (future) Panel Control

This specifies how the auxiliary
input on this door-controller
module is to be used.

France 0
N America

0

European

0

U.K. ACPO

0

Aus/NZ

0

China/H.K.

0

Netherlands 0
Switzerland

0

Auxiliary Relay
Output Mode

0=None, 1=Door Held Open /
Door Forced **, 2=Door
Opener *, 3=future

Operation of the alarm relay on
the door-controller module




NOTE:

Programming selections

whose boxes are grey are not
available for this version.

France

0

N America

□ (no)

European

□ (no)

U.K. ACPO

□ (no)

Aus/NZ

□ (no)

China/H.K.

□ (no)

Netherlands □ (no)
Switzerland

□ (no)

Reader Tamper
Required

9

(yes)

(no)

Whether or not this reader
tamper input is to be monitored.

France

□ (no)

N America

□ (no)

European

□ (no)

U.K. ACPO

□ (no)

Aus/NZ

□ (no)

China/H.K.

□ (no)

Netherlands □ (no)
Switzerland

□ (no)

Reader tamper as
Panel Input

9

(yes)

(no)

France

□ (no)

* Turns on output in this mode when auxiliary input mode is set to challenged RTE and auxiliary input is activated.
** Turns on output in this mode when the condition specified in Door Processing Mode is detected.