Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual
Page 100

96
xL Regional Settings Guide
21-3609E rev1.0
R001
È08 Keypad Selections
N America
10 (1 min)
European
10 (1 min)
U.K. ACPO
10 (1 min)
Aus/NZ
10 (1 min)
China/H.K.
10 (1 min)
Netherlands 10 (1 min)
Switzerland
10 (1 min)
Challenged Door
Held Open Time
Delay Table
How long the door can be held
open without causing an alarm
after a physically-challenged
user enters. Whether or not the
'Challenged' door held open time
applies is based on the
'Challenged' setting for the user.
For details, refer to U001È02
(“Physically Challenged“
setting).
France
10 (1 min)
N America
14 (5 min)
European
14 (5 min)
U.K. ACPO
14 (5 min)
Aus/NZ
14 (5 min)
China/H.K.
14 (5 min)
Netherlands 14 (5 min)
Switzerland
14 (5 min)
Auxiliary Relay
Output Time
Delay Table
How long the door can be held
open after access is granted
without causing an alarm.
France
14 (5 min)
N America
0
European 0
U.K. ACPO
0
Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0
Auxiliary Input Mode
0=None, 1=Mag Lock Bond
Sense, 2=Challenged RTE,
3= (future) Panel Control
This specifies how the auxiliary
input on this door-controller
module is to be used.
France 0
N America
0
European
0
U.K. ACPO
0
Aus/NZ
0
China/H.K.
0
Netherlands 0
Switzerland
0
Auxiliary Relay
Output Mode
0=None, 1=Door Held Open /
Door Forced **, 2=Door
Opener *, 3=future
Operation of the alarm relay on
the door-controller module
NOTE:
Programming selections
whose boxes are grey are not
available for this version.
France
0
N America
□ (no)
European
□ (no)
U.K. ACPO
□ (no)
Aus/NZ
□ (no)
China/H.K.
□ (no)
Netherlands □ (no)
Switzerland
□ (no)
Reader Tamper
Required
9
(yes)
□
(no)
Whether or not this reader
tamper input is to be monitored.
France
□ (no)
N America
□ (no)
European
□ (no)
U.K. ACPO
□ (no)
Aus/NZ
□ (no)
China/H.K.
□ (no)
Netherlands □ (no)
Switzerland
□ (no)
Reader tamper as
Panel Input
9
(yes)
□
(no)
France
□ (no)
* Turns on output in this mode when auxiliary input mode is set to challenged RTE and auxiliary input is activated.
** Turns on output in this mode when the condition specified in Door Processing Mode is detected.