S003

È03 Keypad Selections

ID Number Length

01 – 32

The length of the card ID-number for
primary-format tokens.

20

No. of Bits / Chars

01 – 40

The total number of bits (Wiegand) or
characters (Magstripe) in the card data.

36

Bits per Character

01 – 08

The number of bits used to represent
each character (for magnetic stripe
cards).

8

Card/Token Format

0=none, 1=future
(dallas), 2=Weigand,
3=Magstripe

The basic type of card or token
associated with the primary card format
settings.

2

32-Bit / 9-Digit Card IDs: This requires V1.5 door/elevator controller firmware.

S003

È04 Odd Parity Information (Primary)

Keypad Selections

(left to right on keypad screen)

Name

Selections

Description

Regional Settings Default

Odd Parity
Position

1 – 40

The position of the odd-parity 'checksum'.

36

Odd Parity Start

1 – 40

This is the position of the first data-bit to be
included for odd-parity checking.

18

Odd Parity Length

0 – 40

If either the odd parity length = 0 or even
parity length = 0, then parity will not be
checked.

18

Odd/Even Parity checking:

This feature (which applies only to Wiegand-format cards) helps prevent card misreads.

To disable parity checking:

Set the ‘Parity Length’ to 0 (zero).

S003

È05 Primary Card Format—Even-Parity Checking

Keypad Selections

(left to right on keypad screen)

Name

Selections

Description

Regional Settings Default

Even Parity
Position

1 – 40

The position of the even-parity 'checksum'.

01

Even Parity Start

1 – 40

This is the position of the first data-bit to be
included for even-parity checking.

02

Even Parity Length

0 – 40

This is the number of bits to be included for
even-parity checking. If either the odd parity
length = 0 or even parity length = 0, then
parity will not be checked.

18

Odd/Even Parity checking:

This feature (which applies only to Wiegand-format cards) helps prevent card misreads.

To disable parity checking:

Set the 'Parity Length' to 0 (zero).

S004

È00 Secondary Card Format—Site Code Checking

WARNING:

S004

È

00

S004

È

05

Access Control related

selections are only available with the addition of

the “Feature Expansion Board”.

Keypad Selections

(left to right on keypad screen) Example:


Name

Selections

Description

Regional Settings Default

Check for Site Code

9

(yes)

(no)

Whether or not secondary-format tokens
must have a specific site code to be granted
entry.

†

(no)

Site Code Position

1 – 40

The position of the 1st digit for the
site/system code on these access tokens.

Position value changes depending on
site code length.

02

(U.K. ACPO = 03)

Site Code Length

1 – 16

The length of the site code for secondary-
format tokens (number of digits).

Site code

when represented as a digital #. Can not
exceed 4 digits.

08

(U.K. ACPO = 04)

†

·

02·08

···········

È

Save S004