Save a001 – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 61

Advertising
background image

21-3609E rev1.0

xL Regional Settings Guide

57

A0xx

È05 Keypad Selections

“xx” represents the area number.

WARNING:

These Access Control features are only available with the addition of the “Feature Expansion Board”.

(left to right on keypad screen) N America Example:



Name

Selections

Description

Regional Settings Default

N America

0

European 0
U.K. ACPO

0

Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0

Anti-Pass Back Auto
Reset

0 = No autoreset
1 = 10 Mins
2 = 20 Mins
3 = 30 Mins
4 = 1 Hr
5 = 4 Hrs
6 = 8 Hrs
7 = 12 Hrs

Timed lock out condition for a
card holder resets after they
failed to read their card to
enter/leave previously.

France 0
N America

□ (no)

European

□ (no)

U.K. ACPO

□ (no)

Aus/NZ

□ (no)

China/H.K.

□ (no)

Netherlands □ (no)
Switzerland

□ (no)

Strict Anti-Pass Back
Entry/Exit
Enforcement

9

(yes)

(no)

Whether users will be able to
enter other areas without having
been recorded as leaving the
present one.

France

□ (no)

N America

□ (no)

European

□ (no)

U.K. ACPO

□ (no)

Aus/NZ

□ (no)

China/H.K.

□ (no)

Netherlands □ (no)
Switzerland

□ (no)

No Anti-Pass Back
Outside Check

9

(yes)

(no)

Allows users who didn't 'badge'
out of the facility to re-enter
through an APB controlled area.
With this setting, cards being
used to enter from 'outside' of
the facility will not be checked
for being previously used to exit
(although other APB rules will
still apply). NOTE: Cannot be
their last known area (to allow
this, set APB auto-reset to e.g. 8
hrs).

France

□ (no)

N America

□ (no)

European

□ (no)

U.K. ACPO

□ (no)

Aus/NZ

□ (no)

China/H.K.

□ (no)

Netherlands □ (no)
Switzerland

□ (no)

Lockout all Users on
Invalid Card

9

(yes)

(no)

9

(yes) Lockout all users, even

when access is granted (in case
of global lockout)

France

□ (no)

N America

□ (no)

European

□ (no)

U.K. ACPO

□ (no)

Aus/NZ

□ (no)

China/H.K.

□ (no)

Netherlands □ (no)
Switzerland

□ (no)

Generate Tones on
Invalid Card

9

(yes)

(no)

Keypads sound when an invalid
card is detected.

France

□ (no)

0

·

††††

···········

È

Save A001

И

05

Advertising