Undefined output, Query condition, Output type – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 79

Advertising
background image

21-3609E rev1.0

xL Regional Settings Guide

75

Undefined Output

LCD Screen

? 0000.00 Undef

↓Save

↓?

Bxxx:0

An Undefined Output is
turned off. It can be
changed to any “Query

Condition”

by changing the first 0 to the letter of any

programming section i.e. “S” for System, “A” for Area
etc. (see page 1 for a full list).

Pressing the keypad button below “

↓? “ when the output number

is associated with a module will display the module’s number (i.e.
module # XX), what type it is (e.g. Input/Output module), the
module’s serial number and its output number range.

Query Condition

? qnnn.cc Query
↓Save

↓?

Bxxx:0

“q”

will represent the

first letter of a
programming section.

“nnn”

is the number in the programming section

range that the output is assigned to. E.g. 001 – 016
for Areas, 001 – 050 for Schedules. However,
“System” is 000 – 000 because there are no specific
numbers of anything contained in it. ‘000’ would be
entered for “System”.

“cc”

is the condition code number for the Query

from the Output Selections tables.

A Query can always be changed from one type to
another and can be set as undefined. E.g. a system
siren (S000.07) can be changed to Area 5 is OFF
(A005:14).

Output type

T itt Timer

↓Save

↓?

Bxxx:1

In the next keypad screen
after pressing Save, any
basic output assignment

can be timed or just follow what the output is

supposed to do.

“i”

represents entering a “0” for the output to be a

non-inverted output (e.g. output turns positive) or “1”
for an inverted output (e.g. output turns negative).

“tt”

mainly assigns a time delay to the output

from the Timer Delay Codes Table, page 37. If
00” is entered here it follows a “normal” output
action e.g. “When the system is in alarm”. The
timer delay table begins with entering from 01
being a 1 second timer to 31 being a 1-week
timer. Special entries here are “98” which will
make the output a toggle type. Meaning e.g.
associated keypad command keys when
pressed will turn the output on and the same key
sequence pressed again will turn it off. Entering
99” is an additional way to turn the output off so
it will never activate.

These previous screens are the only ones that will
permit programming simple outputs using the
following Output Selections tables. The next
output programming screens will only appear

when an advanced output has been programmed
using the Director Software and sent to the panel
with a communications method e.g. direct
connection, IP module. After an advanced
equation output has been sent to the panel,
viewing the related output in the “B” output’s
programming section on an LCD keypad will
display additional screens for it like the following:

L ff Logic
↓Save

↓?

Bxxx:2

A Logic equation output
where “ff” is a following
condition code.

Complex-Director

↓Save

↓?

Bxxx:0

A logic equation that is
very complicated and can
only be viewed in the

Director software program.

Error! Bxxx,eee

↓Save Bxxx:2

An output in the outputs
section has been e.g.
improperly programmed.

This condition will only display in the output’s “B”

programming section on an LCD keypad and not
in Status.

Warning: Ordinarily, this type of error will

display as a result of a complicated equation
output done in the Director software and sent to
the panel. This will make it necessary to correct
the error in the Director software and re-send
the information to the panel.

“xxx”

is the output number, 001 – 128, where

the error first occurred. It may not be the same
as the output you are currently viewing. All
outputs after the one affected will display “Error”
and not display any of their settings on the LCD
screen. Outputs after the one in fault will also
cease to operate. All outputs before the one
affected will display their settings and operate
normally.

“eee”

will tell you the type of error. Refer to the

following error list.

Error
Code

Description Possible

Solution

000 Not

applicable.

Notify dealer if
persistent.

001 Program

section
unknown.

Check program
section letter i.e.
“A” for Area, “M”
for module etc.

002 Logic

equation

condition is
unknown.

Panel firmware
version may be
incompatible with
Director ver.

003 Program

section range
number
invalid.

Check the range #
e.g. Input # 001 –
128.

004 Incompatible

Feature Set #

Panel’s Feature
Set needs
upgrading.

005 - 019

Future use.

020 - 029

Critical Error

Notify dealer if
persistent.