Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 47

Advertising
background image

21-3609E rev1.0

xL Regional Settings Guide

43

S005

È00 Keypad Selections

N America

0

European 0
U.K. ACPO

0

Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0

Telco Sequence

0: ULC
1: UL compatible
2: Long
3: MONITOR Standard
(in Canada use 0 or 3)

Call Sequence Details: (P =
Primary phone # attempt; B =
Backup phone # attempt)
0 (ULC): PPBBPPBB / delay 60
min / PPBBPPBB / delay 60 min
/ PPBBPPBB / delay 60 min /
PPBBPPBB.
1 (UL): PPBBPPBBPB / delay
10 min.
2 (Long): PPPPBBBB / delay 10
min / PPPPBBBB / delay 30 min
/ PPPPBBBB / delay 60 min /
PPPPBBBB /
delay 2 hours / PPPPBBBB.
3 (MONITOR Standard): PPBP
/ delay 5 min / PPBP / delay 10
min / PPBP / delay 30 min /
PPBP / delay 60 min / PPBP /
delay 2 hours / PPBP.

France 0

N America

□ (no)

European

□ (no)

U.K. ACPO

□ (no)

Aus/NZ

□ (no)

China/H.K.

□ (no)

Netherlands □ (no)
Switzerland

□ (no)

Telco – prioritized
reporting

9

(yes)

(no)

NOTE:

Programming selections

whose boxes are grey are not
available for this version.

France

□ (no)

N America

9

(yes)

European

9

(yes)

U.K. ACPO

9

(yes)

Aus/NZ

9

(yes)

China/H.K.

9

(yes)

Netherlands 9(yes)

Telco – never allow
blind dialing

9

(yes)

(no)

Dials regardless of detecting
a dial tone.

Switzerland

9

(yes)

Telco

= Telephone Company

S005

È01 Keypad Selections

(left to right on keypad screen)

Name

Selections

Description

Regional Settings Default

Primary Phone
Number

(16 characters)

First Monitoring Station phone number
the system will dial to transmit reports.

The phone number can be preceded with P =pulse
dialing (default), or T =Tone dialing, and can include
D

=2 sec Delay, A =Star key (tone dialing),

#

= Pound Sign (tone dialing), and/or W = Wait for

second dial tone. For Tone dialing, ensure the
phone line supports this.

Blank


S005

È02 Keypad Selections

(left to right on keypad screen)

Name

Selections

Description

Regional Settings Default

Secondary Phone
Number

(16 characters)

Second Monitoring Station phone number
the system will dial to transmit reports, if
dialing the primary phone number is
unsuccessful.

The phone number can be preceded with P =pulse
dialing (default), or T =Tone dialing, and can include
D

=2 sec Delay, A =Star key (tone dialing),

#

= Pound Sign (tone dialing), and/or W = Wait for

second dial tone. For Tone dialing, ensure the
phone line supports this.

Blank

Advertising